SafeSpace™  500 Series 

The SS500 is engineered and tested to withstand large missile impact and 250 MPH static wind loads. Construct safe rooms and storm shelters to FEMA 361 and ICC 500 standards without compromising natural light.


FIRE

OPTIONAL

SMOKE

OPTIONAL


OVERHEAD

COILING



FEMA 361 CERTIFIED

FIRE

RATED


 90 MIN FIRE RATED UNDER UL10B

SMOKE RATED


SMOKE AND DRAFT RATED UNDER UL1784

OVERHEAD COILING


COIL BOX ABOVE OPENING

NO

EGRESS


 NOT AVAILABLE WITH EGRESS

All the specs  you need. Ready for your next project. 

Download Specs


Clear, simple, complete. Download every detail you need.

 Download Details


Get straight to the details. Everything you need all in one click.

Resource Hub

Strength without Sacrifice.

Protect with confidence. Weather any challenge.

Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry's standard dummy text ever since the 1500

Mills High School

Little Rock, AR

House In The Woods

Delavan, WI

Piedmont High School

Piedmont, OK

Lincoln Elementary School

Marion, IL

The details that matter.

Ratings

  • 1-3 hr UL10B


  • 1784 UL Smoke & Draft Labeled



Egress

No egress available

Operation

  • Electric Motor Operation - Outboard Motor 


  • Fail safe motor operator available (See Model SS500F below)

Other Ratings

  • Tornado Resistance: +252 / -252 PSF


  • Tornado Impact: 100 MPH 15 lbs.


  • Hurricane Resistance: +201 / -201 PSF


  • Hurricane Impact:
  •  100 MPH 9 – 15 lbs

Available Sizes

Non-Fire Rated

  • Widths 2'-10" to 20'-3"  
  • Heights 3'-6" to 22'-0"


Fire Rated

  • Widths 4'-4" to 16'-4"  
  • Heights 4'-0" to 22'-0"



  • For larger sizes and custom configurations consult the factory 


Finishes

  • McKeon Sterling Grey
  • RAL Powder Coat

Code Compliance

  • ICC 500 (2014 & 2020): ICC 500/NSSA Standard for the Design & Construction of Storm Shelters


  • FEMA 361 (3rd & 4th Editions): FEMA Standard for the Design and Construction of Safe Rooms for Tornadoes and Hurricanes



  • CCRR-1086 is applicable to SafeSpace 500F & 500F-IS

What makes the SafeSpace™ 500

different?

Wind Pressure & Testing

Wind Pressure  - Design Wind Pressure (DWP) of 200 PSF (subjected to 240 PSF which equals 1.2 times the DWP_ in accordance with ASTM E330) 

Large Missile Impact   - Withstand a large missile impact in accordance with ASTM E1886 for FEMA 361 assemblies

Download our specs.

Specification Key


-G = McKeon Sterling Grey (one color option) 

-PC = Powder Coat, 188 color selection from standard colors (download chart here)

-IS-G = Insulated Slat | McKeon Sterling Grey (one color option)

-IS-PC = Insulated Slat | Powder Coat, 188 color selection from standard colors (download chart here)

No Fire Rating | Non-Insulated

McKeon Sterling Grey (-G)

Standard Finish

RAL Powder Coat (-PC)

188 color selection

No Fire Rating | Insulated

McKeon Sterling Grey (-G)

Insulated (-IS)

RAL Powder Coat (-PC)

Insulated (-IS)

Fire Rated | Non-Insulated

McKeon Sterling Grey (-G)

Standard Finish

RAL Powder Coat (-PC)

188 color selection

Fire Rated | Insulated

McKeon Sterling Grey (-G)

Insulated (-IS)

RAL Powder Coat (-PC)

Insulated (-IS) 

RAL Powder Coat Chart


Explore our RAL 49 Series Series Color Chart, featuring a wide range of standard colors in durable powder coat finishes. For projects requiring specific color matching, custom colors and finishes beyond this chart are also available upon request.

Download our details.

SS500X Details

  • Overhead Coiling
  • Electric Motor Operation - Outboard Motor
  • No egress
  • Non-Fire Rated

SS500F Details

  • Overhead Coiling
  • Electric Motor Operation - Outboard Motor
  • No egress
  • Fire Rated

SS500 Cut Sheet

  • Overhead Coiling
  • Electric Motor Operation - Outboard Motor
  • No egress
  • Fire Rated & Non-Fire Rated 

Download individual PDF sheets, CADs and more BELOW

Download it all.

SS500X Spec Kit

Need more details? Click below to download individual product PDF sheets and get all the details you need at your fingertips.


  • Elevation Detail 
  • Section Detail 
  • Plan Detail 
  • Jamb Details
  • Bottom Bar Detail
  • Coil Box Sizing Chart 


Seamlessly integrate our product into your plans. Click below to download CAD files for precise design compatibility.


  • Elevation Detail 
  • Section Detail 
  • Plan Detail 
  • Jamb Details
  • Bottom Bar Detail
  • Coil Box Sizing Chart 


Access detailed product specifications. Download a Word document template tailored to the finishes listed above for seamless project planning.


SafeSpace 500X-G (McKeon Sterling Grey, Non-Insulated) 

SafeSpace 500X-PC (RAL Powder Coat Selection, Non-Insulated) 


SafeSpace 500X-IS-G (McKeon Sterling Grey, Insulated)   

SafeSpace 500X-IS-PC (RAL Powder Coat Selection, Insulated)   



Get all the product data you need to start specifying with confidence. Download comprehensive info in this section to streamline the process.




• SS500X Series Product Cut Sheet

• RAL Color Chart 





Access third-party testing reports that verify this product meets all required standards. Download the complete listing report below. 




• Listing Report SS500X






SS500F  Spec Kit

Need more details? Click below to download individual product PDF sheets and get all the details you need at your fingertips.


  • Elevation Detail 
  • Section Detail 
  • Plan Detail 
  • Jamb Details
  • Bottom Bar Detail
  • Coil Box Sizing Chart 




Seamlessly integrate our product into your plans. Click below to download CAD files for precise design compatibility.


  • Elevation Detail 
  • Section Detail 
  • Plan Detail 
  • Jamb Details
  • Bottom Bar Detail
  • Coil Box Sizing Chart 




Access detailed product specifications. Download a Word document template tailored to the finishes listed above for seamless project planning.


SafeSpace 500F-G (McKeon Sterling Grey, Non-Insulated, Fire Rated) 

SafeSpace 500F-PC (RAL Powder Coat Selection, Non-Insulated, Fire Rated) 


SafeSpace 500F-IS-G (McKeon Sterling Grey, Insulated, Fire Rated)   

SafeSpace 500F-IS-PC (RAL Powder Coat Selection, Insulated, Fire Rated)   



Get all the product data you need to start specifying with confidence. Download comprehensive info in this section to streamline the process.




• SS500F Series Product Cut Sheet

• RAL Color Chart 







Access third-party testing reports that verify this product meets all required standards. Download the complete listing report below. 




• Listing Report SS500F 








Already know the Wind, Blast, Ballistics or Forced Entry rated product you're looking for?

FEMA & Wind Rated Doors

SafeSpace500   - FEMA 361 & ICC 500 wind rated doors


Operational Wind Loaded Doors

Dynamic 110™ - Operational Wind Load of 110 mph


Blast Resistant

BlastShield™ BL6000 - 10 PSI Blast Rated and ASTM Damage Level Category II


Forced Entry

EntryShield™ FE6000 - 60 Minutes Forced Entry


Ballistics Rated

BulletShield™ BT1000 & BT3000 -  large bore, large caliber handguns up to .44 magnum

Explore more possibilities.

PF3000 Series

Perforated Security Door

View Product

SC3000D Series

Side Coiling Service Door

View Product

HS100

Non Rated Horizontal Coiling Service Door

View Product

IS3000 Series

Insulated Service Door

View Product

SD3000

Non Insulated Service Door

View Product

CS3000 Series

Counter Shutter

View Product

Non Rated Service Doors

Non Rated Security Grilles

G1000 Series

Self Opening Overhead Coiling Grille

View Product

G4000 Series

Self Opening Side Coiling Security Grille

View Product

SG3000 Series

Overhead Coiling Security Grille

View Product

SC3000G

Side Coiling Security Grille

View Product

Dynamic 110

Operational Wind Load of 110 MPH

View Product

FE6000

Forced Entry

View Product

BT1000

Bullet Resistant

View Product

BL6000

Blast Resistant

View Product

SafeSpace 500

Safe Room & Storm Shelter Doors

View Product

Wind and Fortified Security Doors

Still have a question?

Discover more about McKEON's diverse product line and start the design process by reaching out today. We’re ready to help turn your design vision into reality.